Bearing defect frequencies

BPFO, BPFI, BSF and FTF from bearing geometry and shaft speed, with the harmonics and the minimum spectrum Fmax you need to see them.

Inputs

Revolutions per minute.

Hz

For separating electrical faults at 2× line frequency from bearing faults.

Results

Loading the calculation…

This calculation ran in your browser. No value you entered was sent anywhere, and nothing was stored.

How it is calculated

  • BPFO = (n/2)(1 − (d/D)·cosφ)·f, BPFI = (n/2)(1 + (d/D)·cosφ)·f.
  • BSF = (D/2d)(1 − ((d/D)·cosφ)²)·f and FTF = ½(1 − (d/D)·cosφ)·f, with f the shaft frequency.
  • Frequencies are reported in Hz, CPM and orders of running speed, because the three conventions all appear on the same plant.
  • Fmax is suggested as 3.5 × BPFI, the usual minimum for capturing the diagnostic harmonics.

Standards it speaks

Where this stops being true

The equations assume pure rolling contact with no slip, and real bearings slip by one to two per cent under load — so a spectral peak a couple of per cent off a calculated frequency is a match, not a miss. The catalogue geometry here is generic: two bearings with the same bore number from different manufacturers can have different ball counts, and a wrong ball count moves BPFO by a whole order. Where the fault frequency matters, get the geometry from the manufacturer.

Related tools

  • Corrosion rate & remaining life

    Two thickness readings turned into a short-term and a long-term rate, a remaining life and the next inspection date API 510 and 570 would set.

  • Pipe wall thickness & MAOP

    Required wall thickness and maximum allowable operating pressure under B31.3, B31.4 or B31.8, with the class location, joint and temperature factors applied.

  • Pipeline pressure drop

    Single-phase liquid by Darcy–Weisbach with a real Colebrook friction factor, and gas by Weymouth with both Panhandle equations alongside it.