Corrosion rate & remaining life

Two thickness readings turned into a short-term and a long-term rate, a remaining life and the next inspection date API 510 and 570 would set.

Inputs

In years.

t-min from the pressure design, not the nominal minus an allowance.

Results

Loading the calculation…

This calculation ran in your browser. No value you entered was sent anywhere, and nothing was stored.

How it is calculated

  • Short-term rate = (previous − current) / interval. Long-term rate = (nominal − current) / years in service.
  • The governing rate is the larger of the two, as the codes require.
  • Remaining life = (current − minimum required) / governing rate.
  • Next inspection = half the remaining life, capped at ten years.

Standards it speaks

Where this stops being true

Two readings define a line, and corrosion is rarely a line. Under-deposit attack, MIC and CO₂ corrosion all accelerate once initiated, so a rate averaged over ten quiet years will under-predict a mechanism that started last year. The reading also has to be at the same condition monitoring location on the same grid point to mean anything — a 0.3 mm difference is inside the repeatability of a hand-held UT probe on a rough surface, which means a short interval can produce a rate that is entirely measurement noise.

Related tools

  • Bearing defect frequencies

    BPFO, BPFI, BSF and FTF from bearing geometry and shaft speed, with the harmonics and the minimum spectrum Fmax you need to see them.

  • Pipe wall thickness & MAOP

    Required wall thickness and maximum allowable operating pressure under B31.3, B31.4 or B31.8, with the class location, joint and temperature factors applied.

  • Pipeline pressure drop

    Single-phase liquid by Darcy–Weisbach with a real Colebrook friction factor, and gas by Weymouth with both Panhandle equations alongside it.