Bearing defect frequencies
BPFO, BPFI, BSF and FTF from bearing geometry and shaft speed, with the harmonics and the minimum spectrum Fmax you need to see them.
Facilities & integrity
Two thickness readings turned into a short-term and a long-term rate, a remaining life and the next inspection date API 510 and 570 would set.
Loading the calculation…
This calculation ran in your browser. No value you entered was sent anywhere, and nothing was stored.
Two readings define a line, and corrosion is rarely a line. Under-deposit attack, MIC and CO₂ corrosion all accelerate once initiated, so a rate averaged over ten quiet years will under-predict a mechanism that started last year. The reading also has to be at the same condition monitoring location on the same grid point to mean anything — a 0.3 mm difference is inside the repeatability of a hand-held UT probe on a rough surface, which means a short interval can produce a rate that is entirely measurement noise.
BPFO, BPFI, BSF and FTF from bearing geometry and shaft speed, with the harmonics and the minimum spectrum Fmax you need to see them.
A metal-loss defect assessed by both original and modified B31G, giving the failure pressure, the safe operating pressure and the longest defect your MAOP can carry.
Required wall thickness and maximum allowable operating pressure under B31.3, B31.4 or B31.8, with the class location, joint and temperature factors applied.
Single-phase liquid by Darcy–Weisbach with a real Colebrook friction factor, and gas by Weymouth with both Panhandle equations alongside it.