Meana Petro
HS-03IntermediaOla 2IADominio

Monitoreo de Metano y Reporte OGMP 2.0

En una frase

Builds a methane inventory from measurements rather than from emission factors, at the level of detail OGMP 2.0 actually asks for.

El problema

Most reported methane numbers are generic emission factors multiplied by equipment counts. OGMP 2.0 level 4 and 5 require source-level and site-level measurement, and the gap between a factor-based inventory and a measured one is routinely large.

Cómo funciona

Source-level measurements from leak surveys, optical gas imaging and continuous point sensors are reconciled against site-level measurements to produce an inventory with uncertainty at each level. Where reconciliation fails, the discrepancy is reported rather than distributed across sources, because the discrepancy is usually the most informative number in the report.

Datos necesarios

  • Leak detection and repair survey records with source-level quantification
  • Continuous or campaign site-level measurement
  • Equipment inventory with component counts and service classification
  • Operating data: venting, flaring and blowdown events with volumes

Qué obtiene

  • Source-level and site-level methane inventory with uncertainty
  • OGMP 2.0 reporting package at the target level
  • Ranked mitigation list by tonnes abated per unit cost

Qué no puede hacer

Reaching OGMP 2.0 level 5 requires site-level measurement equipment the operator may not have, and this capability cannot substitute analysis for measurement. It will produce a level 3 inventory from existing data and will state plainly what equipment is required to reach levels 4 and 5, rather than presenting an estimate as a measurement.

Cada página de capacidad declara una limitación real. Si un proveedor no puede decirle dónde termina su producto, no le están diciendo la verdad sobre dónde empieza.

Capacidades relacionadas

  • HS-02Intermedia

    Detección de Fugas de Gas y Llama

    Adds optical gas imaging and flame detection on camera to the fixed point detectors, so a leak between detectors is still seen.

    HSE, Emisiones y SeguridadIAIoT
  • HS-04Fundacional

    Monitoreo Inteligente de Antorcha

    Watches the flare on camera to confirm it is lit, estimate how much is being burned, and detect smoking or incomplete combustion.

    HSE, Emisiones y SeguridadIAIoT
  • DF-07Fundacional

    Control Automatizado de Calidad de Datos

    Continuously checks incoming data for stuck sensors, impossible values, missing periods and broken units, and reports the field’s data health as a number.

    Fundamento de DatosTIIA
  • HS-07Intermedia

    Inspección con Drones y Robots

    Flies or drives the inspection route so that people do not have to work at height or enter confined spaces as often.

    HSE, Emisiones y SeguridadIoTIA
  • HS-08Intermedia

    Monitoreo de Ciberseguridad OT

    Watches the control network passively for devices, traffic and commands that should not be there.

    HSE, Emisiones y SeguridadTIIoT