Sizing is downstream of the question that actually matters, which is the relief load. Fire case, blocked outlet, tube rupture, thermal expansion and control-valve failure each give a different required flow, and this tool takes whichever one you type as given — a valve sized perfectly for the wrong scenario protects nothing. The vapour equation also assumes critical flow and a conventional spring-loaded valve; balanced-bellows and pilot-operated valves have different back-pressure behaviour, and two-phase or flashing relief needs the API 520 Part I Appendix D method, which this does not implement.