Meana Petro

Producción y levantamiento

Altura dinámica total y número de etapas de BES

Total dynamic head from net lift, tubing friction and discharge pressure, then the stages and shaft power that head implies.

Datos de entrada

Depth from surface to the working fluid level.

in

0.0006 in for new tubing.

Fluido

Bomba

ft

From the pump catalogue curve.

Horsepower per stage on water.

Resultados

Cargando el cálculo…

Este cálculo se ejecutó en tu navegador. Ningún valor que introdujiste se envió a ningún sitio, y nada se guardó.

Cómo se calcula

  • TDH = net lift (dynamic fluid level) + tubing friction head + discharge pressure expressed as head.
  • Friction uses the Darcy friction factor from a Colebrook–White solution, not a nomograph — so viscosity and roughness actually move the answer.
  • Stages = TDH / head per stage from the pump catalogue curve at your rate; shaft power = stages × power per stage × specific gravity.
  • Pump intake pressure = casing pressure + fluid gradient × submergence.

Estándares que habla

Dónde deja de ser cierto

Single-phase liquid only. Free gas at the intake is what actually limits most ESP installations, and it is not modelled here — below the bubble point the developed head collapses in a way no head-per-stage figure from a water curve will tell you. The head and power per stage are also water-curve values; a viscous crude degrades both, and above roughly 100 cp the correction is large enough that a catalogue curve is no longer usable without it.

Herramientas relacionadas

  • Curva IPR

    One well test turned into an inflow performance curve, a productivity index and an absolute open flow.