BPFO, BPFI, BSF and FTF from bearing geometry and shaft speed, with the harmonics and the minimum spectrum Fmax you need to see them.

Datos de entrada

Revolutions per minute.

Hz

For separating electrical faults at 2× line frequency from bearing faults.

Resultados

Cargando el cálculo…

Este cálculo se ejecutó en tu navegador. Ningún valor que introdujiste se envió a ningún sitio, y nada se guardó.

Cómo se calcula

  • BPFO = (n/2)(1 − (d/D)·cosφ)·f, BPFI = (n/2)(1 + (d/D)·cosφ)·f.
  • BSF = (D/2d)(1 − ((d/D)·cosφ)²)·f and FTF = ½(1 − (d/D)·cosφ)·f, with f the shaft frequency.
  • Frequencies are reported in Hz, CPM and orders of running speed, because the three conventions all appear on the same plant.
  • Fmax is suggested as 3.5 × BPFI, the usual minimum for capturing the diagnostic harmonics.

Estándares que habla

Dónde deja de ser cierto

The equations assume pure rolling contact with no slip, and real bearings slip by one to two per cent under load — so a spectral peak a couple of per cent off a calculated frequency is a match, not a miss. The catalogue geometry here is generic: two bearings with the same bore number from different manufacturers can have different ball counts, and a wrong ball count moves BPFO by a whole order. Where the fault frequency matters, get the geometry from the manufacturer.

Herramientas relacionadas

  • Resistencia remanente B31G

    A metal-loss defect assessed by both original and modified B31G, giving the failure pressure, the safe operating pressure and the longest defect your MAOP can carry.

  • Espesor de pared y MAOP

    Required wall thickness and maximum allowable operating pressure under B31.3, B31.4 or B31.8, with the class location, joint and temperature factors applied.

  • Caída de presión en tubería

    Single-phase liquid by Darcy–Weisbach with a real Colebrook friction factor, and gas by Weymouth with both Panhandle equations alongside it.