Caída de presión en tubería

Single-phase liquid by Darcy–Weisbach with a real Colebrook friction factor, and gas by Weymouth with both Panhandle equations alongside it.

Datos de entrada

Positive when the outlet is higher than the inlet.

Resultados

Cargando el cálculo…

Este cálculo se ejecutó en tu navegador. Ningún valor que introdujiste se envió a ningún sitio, y nada se guardó.

Cómo se calcula

  • Liquid: ΔP = f·(L/D)·ρv²/2 with f from an iterated Colebrook–White solution, plus the elevation head.
  • Gas: Weymouth, Panhandle A and Panhandle B, each solved for the outlet pressure from the squared-pressure form, with z at the average line pressure.
  • Standard conditions are 60 °F and 14.73 psia; length is converted to miles internally because that is what the gas equations are written in.
  • The API RP 14E erosional velocity limit is reported for the gas case so the rate can be checked against it.

Dónde deja de ser cierto

Single phase, isothermal, and — for gas — no elevation profile. Real gathering lines carry liquid, and a two-phase line with holdup in its low points can have several times this pressure drop, arriving in slugs the steady-state number cannot describe. The gas equations also assume fully turbulent flow and hide everything they do not model inside an efficiency factor, which is why three of them are shown: when Weymouth and Panhandle B disagree by twenty per cent, that disagreement is the honest uncertainty, not a reason to pick the convenient one.

Herramientas relacionadas

  • Resistencia remanente B31G

    A metal-loss defect assessed by both original and modified B31G, giving the failure pressure, the safe operating pressure and the longest defect your MAOP can carry.

  • Espesor de pared y MAOP

    Required wall thickness and maximum allowable operating pressure under B31.3, B31.4 or B31.8, with the class location, joint and temperature factors applied.