Meana Petro

Perforación

Hidráulica de barrena y selección de boquillas

Total flow area, nozzle pressure drop, HSI and jet impact force — plus the nozzle size that would put the optimum share of pump pressure at the bit.

Datos de entrada

0.95 for new, round nozzles.

Boquillas (32avos de pulgada)

Resultados

Cargando el cálculo…

Este cálculo se ejecutó en tu navegador. Ningún valor que introdujiste se envió a ningún sitio, y nada se guardó.

Cómo se calcula

  • TFA = Σ π(d/32)²/4 over the open nozzles.
  • Bit pressure drop = ρQ²/(12042·Cd²·TFA²) in ppg, gpm and in².
  • Nozzle velocity = 0.32086·Q/TFA (ft/s); impact force = ρ·Q·Vn/1930.4 (lbf); HSI = ΔPbit·Q/1714 divided by bit face area.
  • Optimum sizes are back-solved from 65 % of standpipe pressure (maximum hydraulic horsepower) and 48 % (maximum impact force).

Estándares que habla

Dónde deja de ser cierto

The discharge coefficient is an assumption, not a measurement: 0.95 is right for a clean, round, new nozzle and wrong for a worn or partially plugged one, and the pressure drop goes as 1/Cd². A bit that has been on bottom for eighty hours is not this calculation. The optimum-share rules are also rules of thumb from roller-cone practice — on a PDC in a hard formation they are, at best, a starting point.