Two thickness readings turned into a short-term and a long-term rate, a remaining life and the next inspection date API 510 and 570 would set.

المدخلات

In years.

t-min from the pressure design, not the nominal minus an allowance.

النتائج

يجري تحميل الحساب…

جرى هذا الحساب داخل متصفحك. لم يُرسل أي رقم أدخلته إلى أي جهة، ولم يُحفظ شيء.

كيف تُحسب

  • Short-term rate = (previous − current) / interval. Long-term rate = (nominal − current) / years in service.
  • The governing rate is the larger of the two, as the codes require.
  • Remaining life = (current − minimum required) / governing rate.
  • Next inspection = half the remaining life, capped at ten years.

المعايير التي تتحدثها

أين تتوقف عن الصحة

Two readings define a line, and corrosion is rarely a line. Under-deposit attack, MIC and CO₂ corrosion all accelerate once initiated, so a rate averaged over ten quiet years will under-predict a mechanism that started last year. The reading also has to be at the same condition monitoring location on the same grid point to mean anything — a 0.3 mm difference is inside the repeatability of a hand-held UT probe on a rough surface, which means a short interval can produce a rate that is entirely measurement noise.