مانا بترو

الإنتاج والرفع

الرفع الديناميكي الكلي للمضخة الغاطسة

Total dynamic head from net lift, tubing friction and discharge pressure, then the stages and shaft power that head implies.

المدخلات

Depth from surface to the working fluid level.

in

0.0006 in for new tubing.

المائع

المضخة

ft

From the pump catalogue curve.

Horsepower per stage on water.

النتائج

يجري تحميل الحساب…

جرى هذا الحساب داخل متصفحك. لم يُرسل أي رقم أدخلته إلى أي جهة، ولم يُحفظ شيء.

كيف تُحسب

  • TDH = net lift (dynamic fluid level) + tubing friction head + discharge pressure expressed as head.
  • Friction uses the Darcy friction factor from a Colebrook–White solution, not a nomograph — so viscosity and roughness actually move the answer.
  • Stages = TDH / head per stage from the pump catalogue curve at your rate; shaft power = stages × power per stage × specific gravity.
  • Pump intake pressure = casing pressure + fluid gradient × submergence.

المعايير التي تتحدثها

أين تتوقف عن الصحة

Single-phase liquid only. Free gas at the intake is what actually limits most ESP installations, and it is not modelled here — below the bubble point the developed head collapses in a way no head-per-stage figure from a water curve will tell you. The head and power per stage are also water-curve values; a viscous crude degrades both, and above roughly 100 cp the correction is large enough that a catalogue curve is no longer usable without it.

أدوات ذات صلة