مانا بترو

الحفر

أحجام البئر وزمن الدوران

Annular and string volumes section by section, then the strokes and the minutes to bottoms-up and to a full circulation.

المدخلات

مقاطع البئر والسلسلة

One row per change of hole size or pipe size, from surface downwards. Paste from a spreadsheet if you have one.

صفLengthHole / casing IDPipe ODPipe ID
1
2
3

المضخة

Per stroke, at 100 % efficiency.

Strokes per minute.

النتائج

يجري تحميل الحساب…

جرى هذا الحساب داخل متصفحك. لم يُرسل أي رقم أدخلته إلى أي جهة، ولم يُحفظ شيء.

كيف تُحسب

  • Annular capacity per section is π(Dh² − Dp²)/4, string capacity is πDi²/4, both computed in SI and reported in bbl and bbl/ft.
  • Effective pump output is displacement × volumetric efficiency. Strokes to bottoms-up is annular volume divided by that.
  • Annular velocity per section is flow rate divided by that section's annular area — the number that decides whether the hole cleans.

المعايير التي تتحدثها

أين تتوقف عن الصحة

It is a geometric volume of an in-gauge hole. Real open hole is washed out, and a caliper commonly shows 5–15 % more volume than the bit size implies — which is exactly the error that lands a cement job short. Where a caliper exists, enter the caliper average as the hole diameter rather than the bit size.

أدوات ذات صلة