كشف تسرب الغاز واللهب
Adds optical gas imaging and flame detection on camera to the fixed point detectors, so a leak between detectors is still seen.
Watches the flare on camera to confirm it is lit, estimate how much is being burned, and detect smoking or incomplete combustion.
Flare volumes are frequently estimated from process balances rather than measured, and an unlit flare — which vents raw gas straight to atmosphere — can go unnoticed for hours, particularly at night or at a remote unmanned site.
Visible and thermal camera analysis classifies flame presence, size, smoke and lift-off, and cross-references against flare gas metering and process events. Burn volume is estimated from flame geometry, calibrated against the flare meter where one exists.
Camera-based volume estimation is approximate — typically within twenty to thirty per cent when calibrated against a meter — and is not a substitute for flare metering for regulatory or fiscal reporting. Heavy fog, sandstorms and a sun-aligned camera angle all degrade classification, and the system reports low visibility rather than guessing at flame status.
كل صفحة قدرة تذكر حداً حقيقياً. إن لم يستطع المورّد إخبارك أين يتوقف منتجه، فلم يُقل لك الحق عن أين يبدأ.
Adds optical gas imaging and flame detection on camera to the fixed point detectors, so a leak between detectors is still seen.
Gets the live sensor data out of the control system safely and stores it at full resolution, which almost nothing else on this site does.
Builds a methane inventory from measurements rather than from emission factors, at the level of detail OGMP 2.0 actually asks for.
Uses the cameras already installed to spot missing protective equipment, people in restricted zones and unsafe proximity to lifting operations.
A technician photographs a nameplate and the equipment record is created or matched, instead of being typed from memory later.